<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>6042</ErrorNumber>
<ErrorFamily>Drum</ErrorFamily>
<ErrorMessage>
DRUM: Hall velocity error - more than 20 percent during drum init.
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This error is reported if the drum velocity as read by the encoder differs by
more than 20% from the targeted drum init velocity, i.e. gross velocity error.
This may be caused by setting drum hppr incorrectly.  Also loose drive belt,
loose pulley, damaged motor ( try "drum spin 60 c" ), grossly out of calibration
drum amp (do "drum cal" and save it), faulty drum amp control/data cable.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resume and report to Creo Response center. Also note velocity error message on
diagnostic monitor if possible.
</text></DescriptionText>
</OperatorAction>
<Cause>
drum hppr set incorrectly
</Cause>
<Cause>
Loose pulley
</Cause>
<Cause>
Damaged motor
</Cause>
<Cause>
Grossly out of calibration drum amp.
</Cause>
<Cause>
Faulty drum amp control/data cable.
</Cause>
<Cause>
Bad encoder
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/drum_cfg_hppr.xml</LinkAddress><LinkTitle>NVS: drum hppr</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:27 2008 PST
</Updated>
<Links>
</Links>
</Error>